Industrial Dry Rooms | ACH Solutions

Industrial Dry Rooms

Precision low-humidity controlled environments engineered to dew points as low as −65°C.

Industrial Dry Rooms | ACH Solutions

Engineered Low-Humidity
Controlled Environments

Below 1% RH or to a precise dew point as low as −65°C — held continuously under full production load. Standard HVAC cannot reach it; dedicated desiccant technology can.

A dry room — also called a low-humidity room, dew point room, or dry cleanroom — is a controlled environment where relative humidity is maintained at extremely low levels. Unlike standard HVAC conditioning, industrial dry rooms require dedicated desiccant dehumidification, vapour-sealed construction, and precision control systems that hold set points continuously under load.

In lithium battery manufacturing, moisture causes electrolyte degradation, thermal runaway risk, and reduced cell capacity. In semiconductor dry rooms, uncontrolled humidity leads to yield loss and corrosion. In pharmaceutical dry rooms, hygroscopic APIs absorb moisture and fail specification.

As a dedicated dry room manufacturer, ACH Solutions delivers complete dry room construction and validation — from engineering and in-house fabrication through to qualified handover.

Completed Dry Room
Completed dry room interior with perimeter workbenches and sealed modular panel walls
Have a dew point target in mind?Tell us your process and we'll size the system to it.
Get a Dry Room Quote →

Dry Room Performance Parameters

Every specification is sized to your exact process requirement — never pulled from a catalogue.

Dew Point Range
−20°C to −65°C — sized to your exact process requirement
Relative Humidity
<1% RH achievable at steady state under full production load
Temperature Control
±0.5°C temperature uniformity across the working zone
Dehumidification
Rotary desiccant wheel with regeneration — no refrigerant dew point limitations
Vapour Envelope
Vapour-barrier modular panels, sealed penetrations, airlock pressure cascade
Monitoring
Continuous dew point monitoring, BMS integration, real-time alarms
Standards
ISO 14644, GMP, ASHRAE 90.1, NBC/OBC — full validation documentation available
Need these parameters in a formal spec?We provide full documentation for your validation team.
Request Specifications →

Moisture Load Analysis First.
Then We Design the Dry Room.

Every ACH dry room design begins with a complete moisture load analysis. We calculate occupancy moisture generation, process moisture loads, envelope infiltration rates, and airlock ingress — establishing the true dehumidification duty before selecting a single piece of equipment.

This prevents the most common dry room failure: an undersized system that cannot hold dew point under real production conditions.

We then specify and install the full system: rotary desiccant dehumidification with regeneration circuits, vapour-sealed modular panel construction, pressure-cascade airlock management, precision temperature control, and real-time BMS monitoring. For regulated industries, documentation is structured from day one for full qualification.

Dry room process bench with sinks, equipment, and interior viewing window
Worried your current system can't hold dew point?We'll run the moisture load analysis and tell you straight.
Request an Analysis →

Six Core Capabilities in
Every Dry Room Project

Not observers of construction — execution owners accountable for dew point performance from analysis through validated handover.

Moisture Load Analysis

Full calculation of dehumidification duty under actual occupancy — preventing an undersized system that loses dew point under load.

Desiccant System Design

Rotary desiccant wheel with regeneration — the only practical technology for −40°C to −65°C dew points in battery and semiconductor applications.

Vapour-Sealed Construction

Every panel joint, service penetration, door frame, and airlock seal is vapour-tight. Vapour infiltration is the number-one dry room failure mode.

Airlock Entry Management

Engineered airlock sequence with pressure cascade — maintaining dew point under full occupancy and production entry frequency.

Real-Time BMS Monitoring

Continuous dew point monitoring with BMS integration and real-time alarms — full visibility of conditions under live production load.

Retrofit Within Active Facilities

Most ACH dry room projects are retrofits inside operating production facilities — delivered without disrupting live adjacent processes.

Want all six capabilities on your project?One accountable team from analysis to handover.
Start Your Project →

Where Dry Rooms Are
Non-Negotiable

ACH Solutions builds industrial dry rooms for every sector where moisture control is critical to product quality, safety, and regulatory compliance. If your process requires a dew point below −10°C, standard HVAC conditioning will not meet the requirement.

Operating in one of these sectors?We've delivered dry rooms across all of them.
Talk to Our Team →

From Dew Point Specification
to Validated Handover

Every ACH dry room project follows a structured six-step process. Engineering is never rushed — construction never starts before the humidity control strategy is fully resolved.

  1. 01

    Process & Dew Point Definition

    Define exact dew point target, occupancy load, process moisture sources, and production schedule.

  2. 02

    Desiccant System & Envelope Design

    Desiccant sizing, regeneration circuit design, airlock sequencing, vapour barrier specification, BMS integration.

  3. 03

    In-House Panel Fabrication

    Vapour-sealed modular panels, airlock door systems, and service penetration assemblies manufactured in-house.

  4. 04

    Site Installation & Integration

    Panel installation, desiccant unit and ductwork integration — within active facilities using phasing as required.

  5. 05

    Commissioning & Verification

    Full commissioning under actual production load — dew point mapping, airlock testing, BMS checks.

  6. 06

    Validated Handover

    Full qualification documentation and complete turnover package ready for immediate use by your quality team.

Your dew point requirement might be different. Our engineering handles that.Tell us your spec — we respond within one business day.
Request a Scope Call →

Why Dry Room Engineering
Determines Performance

ACH SolutionsDry Room Specialist

Dew Point
−20°C to −65°C — designed to your exact process load
System Sizing
Full moisture load analysis — all variables calculated
Dehumidification
Rotary desiccant wheel — no refrigerant limitations
Vapour Envelope
Fully sealed — every joint and penetration vapour-tight
Airlock Design
Engineered pressure cascade — moisture ingress controlled
Validation Docs
Structured from day one — complete package at handover
Timeline
8–16 weeks (fit-outs) · 16–28 weeks (new builds)

General ContractorStandard HVAC

Dew Point
Typically limited to −10°C to −20°C
System Sizing
Equipment from catalogue — commonly undersized
Dehumidification
Refrigerant coils — unable to achieve battery dew points
Vapour Envelope
Standard construction — vapour infiltration most common failure
Airlock Design
Often a single door — no moisture management per entry
Validation Docs
Not available — separate consultant required
Timeline
24–40+ weeks sequential conventional construction
Don't risk a system that can't hold dew point.Work with a dedicated dry room specialist from day one.
Request a Consultation →

Dry Room Questions
Answered Directly

Using rotary desiccant wheel technology, ACH Solutions achieves dew points as low as −65°C. Lithium battery cell assembly typically requires −40°C to −60°C, and pharmaceutical dry rooms may require −20°C to −40°C. We size the system to your actual process load under full occupancy.

A cleanroom controls airborne particulate contamination to an ISO 14644 classification. A dry room controls humidity using desiccant dehumidification. ACH Solutions designs and builds combined environments where your process requires both.

Yes — retrofit within active production facilities is one of our most common project types, delivered without disrupting live adjacent processes.

Most dry room fit-outs deliver in 8–16 weeks. Complex new builds or combined dry room and cleanroom environments typically deliver in 16–28 weeks.

Standard air conditioning has a practical lower limit of approximately −10°C to −20°C dew point. Rotary desiccant wheel dehumidification adsorbs moisture from the air and regenerates with heat — no refrigerant-based limitation. This is the only practical technology for −40°C to −65°C dew points.

Lithium-ion battery and EV battery manufacturing, semiconductor and electronics, pharmaceutical manufacturing, aerospace, medical device manufacturing, and advanced materials R&D. ACH Solutions has delivered dry rooms across all of these sectors.

Still have a question about your specific process?Ask us directly — real reply within one business day.
Ask a Question →

In-House Capability,
End to End

From sealed-shell construction through to fully fitted controlled environments — every dry room is built and verified under one roof.

Completed dry room interior with perimeter workbenches and sealed modular panel walls
Delivered

Fitted Workstation Environment

Dry room entry doors and storage cabinets in a sealed controlled environment
Access Control

Sealed Entry & Storage

Dry room process bench with sinks, equipment, and interior viewing window
Process Ready

Process Bench & Equipment

Pre-fit-out controlled environment shell with vapour-sealed wall construction
Construction

Installed Dry Room

Planning a dry room build?In-house fabrication keeps your schedule and quality in our control.
Get a Dry Room Quote →

Let's Define Your
Dry Room Requirement

Tell us your dew point target, room size, and industry. Our engineering handles the moisture load analysis — and you get a system sized to perform under real production conditions.